GE Security
g
NX-6 WIRING DIAGRAM
1
AUX 4
(SMOKE +)
3
COM
2
COM
4
COM
POS
COM
DATA
5
3
12
AUX +
ZONES
6
COM
BELL +
BELL -
AC
AC
EARTH
KEYPAD
Aux. Outs 1 - 3 Current
limited to 250 microamps
when output is positive &
250 mA when output is
negative.
LIGHTNING PROTECTION
THE CONTROL PANEL
MUST BE EARTH GROUNDED
FOR LIGHTNING PROTECTION
TO WORK EFFECTIVELY.
CE APPROVED TRANSFORMER.
16,5Vac / 35VA
DO NOT
CONNECT
230VAC TO
TERMINAL
STRIP.
230V AC
50Hz
PRIMARY
FUSE
500mA.
BUILT IN SIREN DRIVER
FOR 15 OR 30 WATT
SPEAKERS 4,8 OR 16
OHM LOAD.
TO ADDITIONAL
KEYPADS AND
EXPANSION
DEVICES.
MAX TOTAL WIRE RUN IS 800m.
MAX NUMBER OF DEVICES IS 8
KEYPADS + 3 OTHER DEVICES.
KEYPAD POS AND AUX + TERMINALS
ARE LIMITED TO 1 AMP.
THE TOTAL STANDBY CURRENT DRAWN FROM
TERMINALS AUX+AND KEYPAD POS WHEN
ADDED TOGETHER, MUST NOT EXCEED 1AMP
WITH A 35VA TRANSFORMER.
UNDER FULL-LOAD, THE CONTROL PANEL
NO LONGER PROCESSES SENSOR TRIPS
AT 9.25 VOLTS.
1 NORMALLY OPEN
CONTACT AND
1 NORMALLY CLOSED
CONTACT WITH E.O.L.
RESISTOR.
3.3K
E.O.L.
ANY ZONE
TERMINAL
ANY COM
TERMINAL
NORMALLY CLOSED
CONTACT WITH E.O.L.
RESISTOR.
3.3K
E.O.L.
ANY ZONE
TERMINAL
ANY COM
TERMINAL
ANY ZONE
TERMINAL
NORMALLY OPEN
CONTACT WITH
E.O.L. RESISTOR.
3.3K
E.O.L.
ANY COM
TERMINAL
DOUBLED ZONE
CONFIGURATION
USED AS A FIRE
ZONE.
3.74K
E.O.L.
ANY ZONE
TERMINAL
ANY COM
TERMINAL
ANY COM
TERMINAL
DOUBLED ZONE
CONFIGURATION.
The 3.74K resistor
is for zones 1 - 6.
The 6.98K resistor
is for zones 7 - 12.
6.98K
E.O.L. (7 - 12)
ANY ZONE
TERMINAL
3.74K
E.O.L. (1 - 6)
IF A DOUBLED ZONE
IS USED AS A FIRE ZONE,
THE HIGH ZONE (7 - 12)
IS NOT USABLE.
EUROPEAN
1E.O.L./ 2E.O.L.
2 WIRE SMOKE E.O.L.
BLUE
GRAY
BRN
GOLD
680 ohm
ZONE DOUBLING
ZONES 7 - 12
BLUE
WHT
GRAY
BRN
6.98K
BRN
ZONE DOUBLING
ZONES 1- 6
ORG
VIOLET
YEL
BRN
3.74K
BRN
E.O.L
RESISTORS
2 NORMALLY
OPEN CONTACT
AND 2 NORMALLY
CLOSED CONTACT
WITH E.O.L.
RESISTOR.
3.3K
E.O.L.
ANY ZONE
TERMINAL
ANY COM
TERMINAL
EUROPEAN DOUBLE
E.O.L. CONFIGURATION
ANY ZONE
TERMINAL
ANY COM
TERMINAL
3.3K
E.O.L.
3.3K
E.O.L.
TAMPER
CONTACT
FOR VOLTAGE OUTPUT
PROGRAM LOCATION 37,
SEGMENT 2, FEATURE 1.
ALL ZONE INPUTS ARE SUPERVISED.
(
S
u
p
e
r
v
i
s
e
d
)
(
S
u
p
e
r
v
i
s
e
d
)
M
A
K
E
S
U
R
E
T
O
P
R
O
G
R
A
M
L
O
C
3
7
,
S
E
G
6
,
O
P
T
I
O
N
1
F
O
R
2
-
W
I
R
E
S
M
O
K
E
L
O
O
P
.
N
X
-
1
0
8
E
N
X
-
1
1
6
E
N
X
-
1
2
4
E
N
X
-
1
2
0
8
E
N
X
-
1
2
4
8
E
N
X
-
1
4
8
E
N
X
-
1
3
0
8
E
N
X
-
1
3
1
6
E
N
X
-
1
3
2
4
E
N
X
-
1
3
4
8
E
-
I
C
O
N
N
X
-
1
5
0
8
E
N
X
-
1
5
1
6
E
K
E
Y
P
A
D
P
A
R
T
#
AUXOUT
R
E
D
B
L
A
C
K
THESE LEDs ARE FOR
PROPER CIRCUIT
OPERATION ONLY
CHECK RE
QUIRED BATTERY
STANDBY TIME WITH LOCAL
REGULATIONS. CONTROL
PANEL DRAWS
60mA IN
STANDBY.
Transmission of burglary/fire alarms
direclty to a police/fire brigade
emergency number is NOT permitted.
Alarms should be transmitted to an
authorized central station.
WARNING – TO PREVENT RISK
OF ELECTRIC SHOCK- ALWAYS
DISCONNECT THE TELEPHONE
LINE PRIOR TO SERVICING.
PROGRAM
BOX TAMPER
Aux 4 defaults to SMOKE +
& can be used as Zone 7
for 2-wire smoke loop. Connect
Between Aux 4 & COM.
Program LOC 37, SEG 6, OPT 1.
Aux. Out 4 (as Smoke +)
Current limited to 250 mA
when output is positive and
250 microamps when
output is negative.
THIS LED IS LIT DURING
COMMUNICATION.
IF BOX TAMPER IS ENABLED IN LOC 37,
CONNECT A NORMALLY CLOSED
SWITCH TO THESE PINS.
AUDIO TAP
1
D
U
B
L
I
N
,
I
R
E
L
A
N
D
NX-6-EUR Installation manual Page 91 23/12/04