CADDX NX-6 Manual de instalación Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 104
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
GE Security
g
[*]-[CHIME] ACTIVATING WALKTEST
1. Enter [*]-[CHIME]
The LCD screen will prompt you for a “master
code”.
2. Enter [mastercode] The LCD screen will display the “walktest mode”
3. Activate all sensors to test
Each activation of a sensor is confirmed with a
“ding dong” sound. The zone texts of the sensors
who have reacted, are displayed one by one on the
screen.
4. Enter [mastercode] The walktest mode is left.
Remark:
1. All activations and restore conditions occurred during the walk test, can
be verified by consulting the memory file (see function [*]-[9]-[0])
2.
A walk test mode is not possible if any partition is armed or if the
communicator is active.