GE Security
g
General options
LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data)
Location 37 is used to enable various system feature and reporting options.
Segment 1
1 = On: if siren sounds for “Telephone Line Cut” when armed
2 = On: if siren sounds for “Telephone Line Cut” when disarmed
3 = On: if siren blast at arming (pulse)
4 = On: if siren blast at exit expiration (pulse)
5 = On: if siren blast at closing kiss-off (pulse)
6 = On: if siren sounds during a “Cross Zone” verification time
7 = On: if siren sounds for a zone or box tamper
8 =
On: if siren blasts 1 time for keyswitch or wireless arming; 2 times
for disarming
Segment 2
1 =
On: if siren driver should be a voltage output. Off: if on-board siren
driver is enabled
2 = On: if sirens sound for expander trouble
3 =
On: for zones to restore immediately. Off: for zones to restore only
when the siren is off or disarmed
4 =
On: if dynamic battery test is performed at arming. Off: if dynamic
battery test is performed at disarming (See location 40)
5 = On: if battery missing test is performed every 12 seconds
6 = On: if manual bell test is performed during [*]-[4]-[4] test function
7 =
On: if manual communicator test is performed during [*]-[4]-[4] test
function
8 = On: if Box Tamper terminals on the control panel are enabled
Segment 3
1 = On: if box tamper report is enabled
2 = On: if AC fail reporting is enabled
3 = On: if low battery reporting is enabled
4 = On: if Aux. power overcurrent report is enabled
5 = On: if siren supervision report is enabled
6 = On: if restore telephone line cut report is enabled
7 = On: A+B Alarm. Off: cross-zoning
8 = On: if expander trouble reporting is enabled
Segment 4
1 = On: if fail to communicate report is enabled
2 = On: if log full report is enabled
3 = On: if autotest report is enabled
4 = On: if start/end programming report is enabled
5 = On: if end download report is enabled
6 = On: if sensor low battery report is enabled
7 = On: if sensor missing report is enabled
8 = On: if autotest report is enabled ONLY when the system is armed
NX-6-EUR Installation manual Page 50 23/12/04