GE Security
g
Communicator codes for slow speed formats only
LOCATIONS 56-83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER, OR
WHEN USING A SLOW FORMAT SUCH AS 4+2. WHEN USING CONTACT ID OR SIA,
THERE IS NO NEED TO PROGRAM THESE LOCATIONS.
LOCATION 56 - RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,
numerical data)
Location 56 contains the event code for any zone “Alarm” and “Restore” for a 4+2 and
3+1 format. For a 4+2 format, the digit programmed in this location will be sent as the
tens digit of the alarm event code. As ones digit, the zone number (1-F) will be reported
(e.g. zone 16 = 1, zone 10 = A).
This location contains 8 segments. Any segment left as “0” will follow the segment 1
selection.
Segments 1-2 contain the alarm code for zone 1 to 16.
Segments 5-6 contain the restore code for zone 1 to 16.
Segment 1
Zones 1-15, “Alarm Code”
Segment 2
Zone 16, “Alarm Code”
Segment 3
Reserved
Segment 4
Reserved
Segment 5
Zones 1-15, “Restore Code”
Segment 6
Zone 16, “Restore Code”
Segment 7
Reserved
Segment 8
Reserved
LOCATION 57 - BYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments,
numerical data)
Location 57 contains the event code for a zone “Bypass” with a 4+2 and 3+1 format. For
a 4+2 format, the digit programmed in this location will be sent as the tens digit. As ones
digit, the zone number (1-F) will be reported (e.g. zone 16 = 1, zone 10 = A).
This location contains 8 segments. Any segment left as “0” will follow the segment 1
selection.
Segments 1-2 contain the bypass code per bank of 15 zones. Segments 3-8 are
reserved.
When unbypassing a zone, the restore code of location 56 will be used.
Segment 1
Zones 1-15, “Bypass Code”
Segment 2
Zone 16 “Bypass Code”
Segment 3-8
Reserved
NX-6-EUR Installation manual Page 59 23/12/04