Programming partition parameters
LOCATIONS 88-109 ARE FOR PROGRAMMING DIFFERENT ACCOUNT CODES
AND/OR FEATURES FOR EACH PARTITION. IF A LOCATION IS LEFT
UNPROGRAMMED, THE FEATURE FOR PARTITION 1 AND THE ACCOUNT CODE
FOR THE PHONE NUMBER WILL BE USED
LOCATION 88 - ACCOUNT CODE FOR PARTITION 1 (6 segments, numerical data)
Location 88 contains the account code that is sent when partition 1 is reported. If location
88 is left unprogrammed (all “10”s), then the account code corresponding to the phone
number that is dialled will be used. If the account code is less than six digits, program a
“10” in the segment immediately after the last digit of the account code. If the account
code is 6 digits long, program all 6 segments.
LOCATION 89 - ACCOUNT CODE FOR PARTITION 2 (6 segments, numerical data)
Location 89 contains the account code that is sent when partition 2 is reported. If location
89 is left unprogrammed (all “10”s), then the account code corresponding to the phone
number that is dialled will be used. If the account code is less than six digits, program a
“10” in the segment immediately after the last digit of the account code. If the account
code is 6 digits long, program all 6 segments.
LOCATION 90 - PARTITION 2 FEATURE AND REPORTING SELECTIONS (5 segments, feature
selection data)
Location 90 is used to enable certain features that the user can access or see from the
keypad of the system. In addition, certain communicator reports are enabled in this
location. Each of these features can be enabled by partition. This location contains 5
segments, with eight possible features per segment. Refer to location 23 for the feature
selections. If all the segments are blank (nothing enabled), the features for partition 1 will
be used.
LOCATION 91 - PARTITION 2 ENTRY EXIT TIMERS (6 segments, numerical data)
Location 91 is used to enter the entry and exit times, in seconds. There are 2 separate
entry and exit times. Valid entries are 10-255 seconds. If all the segments are “0”, the
entry and exit times for partition 1 will be used.
Segment 1
Entry time 1
Entry time that will be used when a delay 1 zone
type initiates an entry delay
Segment 2
Entry time 2
Exit time that will be used for all zones designated
as delay 1
Segment 3
Entry time 3
Entry time that will be used when a delay 2 zone
type initiates an entry delay
Segment 4
Entry time 4
Exit time that will be used for all zones designated
as delay 2
Segment 5
Reserved
Segment 6
Reserved
LOCATION 92-109 - RESERVED