GE Security
g
ALARM AND RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1 Zone 1-15 Alarm code 0
Segment 2 Zone 16 Alarm code 0
Segment 3-4 Reserved 0
Segment 5 Zone 1-15 Restore code 0
Segment 6 Zone 16 Restore code 0
56 58
Segment 7-8 Reserved 0
BYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1 Zone 1-15 Bypass code 0
Segment 2 Zone 16 Bypass code 0
57 58
Segment 3-8 Reserved 0
TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1 Zone 1-15 Tamper Code 0
Segment 2 Zone 16 Tamper Code 0
58 59
Segment 3-8 Reserved 0
TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1 Zone 1-15 Trouble Code 0
Segment 2 Zone 16 Trouble Code 0
59 59
Segment 3-8 Reserved 0
SENSOR LOW BATTERY COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1 Zone 1-15 Sensor Low Battery Code 0
Segment 2 Zone 16 Sensor Low Battery Code 0
60 60
Segment 3-8 Reserved 0
SENSOR MISSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1 Zone 1-15 Sensor Missing Code 0
Segment 2 Zone 16 Sensor Missing Code 0
61 60
Segment 3-8 Reserved 0
COMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY
62 60 DURESS 0-0
63 61 AUXILIARY 1 (fire) 0-0
64 61 AUXILIARY 2 (medical alarm) 0-0
65 61 KEYPAD PANIC 0-0
66 61 KEYPAD MULTIPLE CODE ENTRY TAMPER 0-0
67 61 BOX TAMPER / BOX TAMPER RESTORE 0-0-0-0
68 62 AC FAIL / AC RESTORE 0-0-0-0
69 62 LOW BATTERY / LOW BATTERY RESTORE 0-0-0-0
70 62 POWER SHORT / POWER SHORT RESTORE 0-0-0-0
71 62 BELL TAMPER / BELL TAMPER RESTORE 0-0-0-0
72 62 TELEPHONE LINE CUT RESTORE 0-0-0-0
73 63 Reserved 0-0
74 63 EXPANDER TROUBLE / EXPANDER TROUBLE RESTORE 0-0-0-0
75 63 FAILURE TO COMMUNICATE 0-0
76 63 LOG FULL COMMUNICATOR CODE 0-0
OPENING CODE COMMUNICATOR CODE
Segment 1 Opening Code for Codes 1-15 0
Segment 2 Opening Code for Codes 16-30 0
Segment 3 Opening Code for Codes 31-40 0
77 63
Segment 4-8 Reserved 0
CLOSING COMMUNICATOR CODE
Segment 1 Closing Code for Codes 1-15 0
Segment 2 Closing Code for Codes 16-30 0
Segment 3 Closing Code for Codes 31-40 0
78 64
Segment 4-8 Reserved 0
79 64 AUTOTEST COMMUNICATOR CODE 0-0
80 64 RECENT CLOSING AND EXIT ERROR 0-0
NX-6-EUR Installation manual Page 86 23/12/04