Guard codes (Sweden)
User codes 16 and 17 can be considered as so called “guard codes”. In this case, user
codes 16 and 17 cannot be programmed or changed anymore via a master code. They
can only be changed via downloading. Guard code 16 will be able to arm/disarm at any
time. Guard code 17 will only be able to arm/disarm during an alarm condition. Only
when an alarm condition occurs, guard code 17 will be able to disarm the system. After
having evaluated the alarm condition, guard code 17 can arm the system again but will
not be able to disarm anymore (see location 41, segment 1, option 7).
Group bypass
A designated group of zones can be programmed to bypass by pressing [Bypass]-[0]-[0]-
[Bypass] prior to arming (see locations 111-169 segment 2).
Immediate restore by zone
The NX-6 can be programmed to send alarm and restore reports as soon as they occur,
or to wait until the siren time has expired or the system has been disarmed. (see location
37 segment 2).
Internal event log
Up to 512 events can be stored in memory together with the date and time of the event.
These events can be viewed later on via the LCD keypad, or by downloading. All
reportable events are reported to the log.
Keypad activated panics
The NX-6 has three keypad activated panics that will send reports to the central station,
auxiliary 1 (Fire), auxiliary 2 (Medical) and keypad panic. Auxiliary 1 will activate the
steady (Fire) siren, auxiliary 2 will sound the keypad, and the keypad panic can be
programmed to be silent or audible (see location 23 segment 1).
Keypad shutdown mode
This feature will extinguish all the LED’s on the keypad, except the “Power” LED, after 60
seconds have elapsed without a keypress. Pressing a valid user code (not an installer
code) will light up all the LED’s (see location 41, segment 1, option 5). This option
requires bilingual LCD keypads. This option is an alternative for LED-extinguish.
Keypad sounder control
The NX-6 can be programmed to sound the keypad sounder for certain events (see
location 39).
Keypad tamper
If this option is enabled, the NX-6 will disable the keypad for 60 seconds, and will
communicate a tamper signal to the central station whenever 30 keypresses are entered
without producing a valid code (see location 23 segment 1).
Keyswitch arm/disarm
Any zone on the NX-6 can be programmed as a momentary or maintained keyswitch
zone. If a zone has been programmed as a momentary keyswitch, momentary shorts on
this zone will arm/disarm the control. A zone can be also being programmed as a
maintained keyswitch. The control panel will be armed as long as such a zone is shorted.
If opening/closing reports are sent, the user code will be 99 (see “default zone
configurations”)
LED extinguish
This feature will extinguish all the LED’s on the keypad, except the “Power” LED, after 60
seconds have elapsed without a keypress. Pressing any numeric key will light up all the
LED’s (see location 23 segment 2).