g
LOCATION 159 - CONFIGURATION GROUP 25 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 160 - CONFIGURATION GROUP 26 ALARM EVENT CODE (1 segment, numerical data)
Location 160 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 161 - CONFIGURATION GROUP 26 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 162 - CONFIGURATION GROUP 27 ALARM EVENT CODE (1 segment, numerical data)
Location 162 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 163 - CONFIGURATION GROUP 27 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 164 - CONFIGURATION GROUP 28 ALARM EVENT CODE (1 segment, numerical data)
Location 164 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 165 - CONFIGURATION GROUP 28 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
NX-6-EUR Installation manual Page 76 23/12/04