CADDX NX-6 Manual de instalación Pagina 60

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 104
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 59
GE Security
g
LOCATION 58 - TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS (8 segments,
numerical data)
Location 58 contains the event code for a zone “Tamper” with a 4+2 and 3+1 format. For
a 4+2 format, the digit programmed in this location will be sent as the tens digit. As ones
digit, the zone number (1-F) will be reported (e.g. zone 16 = 1, zone 10 = A).
Any segment left as “0” will follow the segment 1 selection.
Segments 1-2 contain the tamper code per bank of 15 zones.
Segments 3-8 are reserved.
To report a restore, the restore code of location 56 will be used.
Segment 1
Zones 1-15, “Tamper Code”
Segment 2
Zone 16 “Tamper Code”
Segment 3-8
Reserved
LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments,
numerical data)
Location 59 contains the event code for a zone “Trouble” with a 4+2 and 3+1 format. For
the 4+2 format, the digit programmed in this location will be sent as the tens digit. As
ones digit, the zone number (1-F) will be reported (e.g. zone 16 = 1, zone 10 = A).
Any segment left as “0” will follow segment 1 selection.
Segments 1-2 contain the trouble code per bank of 15 zones.
Segments 3-8 are reserved.
To report a restore, the restore code of location 56 will be used.
Segment 1
Zones 1-15, “Trouble Code”
Segment 2
Zone 16 “Trouble Code”
Segment 3-8
Reserved
NX-6-EUR Installation manual Page 60 23/12/04