50
APPENDIX 2
This document lists the event reporting codes for Ademco Contact ID reporting. The event codes are programmed
by placing a number from 0-15 in the Data 1 location of the communicator code for the event being reported. For
zones, programming a "0" as the Data 1 location will result in an automatic selection of the event code depending
on the zone type choosing from Fire, Panic, and Burglary. The Data 2 and Data 3 are sent as the Zone Identifier.
PROGRAMMED DATA 1 ADEMCO EVENT CODE DEFINITION
0 122 Silent Panic (Only for Loc. 332)
1 110 Fire
2 120 Panic
3 130 Burglary
4 131 Perimeter Burglary
5 132 Interior Burglary
6 133 24 hour Burglary
7 134 Entry/Exit Burglary
8 135 Day/Night Burglary
9 150 Non-burg 24 hour
10 121 Duress
11 100 Medical Alarm
12 123 Audible Panic
If the following numbers are programmed for the Contact ID event code, the event code will be made up of 3
alternate programming locations according to the following:
PROGRAMMED DATA 1 PROGRAMMING LOCATIONS
13 365,366,367
14 369,370,371
15 373,374,375
The following event codes are sent automatically, but must be enabled by programming a 1 in the communicator
code location for that report:
REPORTING EVENT ADEMCO EVENT DIGIT LOCATIONS
Keypad Tamper 137 336
Autotest 602 340
Opening/Closing 401 348 / 350
Cancel 406 354
A.C. Loss 301 356
A.C. Restore 301 376
Restore Event code for alarm 364
Zone Bypass 570 368
Zone Trouble 380 372
Low Battery 302 360
Battery Restore 302 376
Battery Test Fail 309 360 / 255
Battery Test Restore 309 376
Late to Close 404 592
Early to Open 400 588
Download Complete 412 596
Expander Module Trouble 333 378
Expander Trouble Restore 333 511
RF Loss of Supervision 381 (For these two, see
RF Transmitter Low Battery 384 9090 Installation Manual)