NX-8E CONTROL
25
LOCATION 47 - AUXILIARY OUTPUT #1, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table XI-1 on page 25 to select the event that will activate Auxiliary Output 1.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 1, Location 46). Programming a "0" makes the output follow the event.
LOCATION 48 - AUXILIARY OUTPUT #2, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table XI-1 on page 25 to select the event that will activate Auxiliary Output 2.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 2, Location 46). Programming a "0" makes the output follow the event.
LOCATION 49- AUXILIARY OUTPUT #3, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table XI-1 on page 25 to select the event that will activate Auxiliary Output 3.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 3, Location 46). Programming a "0" makes the output follow the event.
LOCATION 50- AUXILIARY OUTPUT #4, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table XI-1 on page 25 to select the event that will activate Auxiliary Output 4. .
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 4, Location 46). Programming a "0" makes the output follow the event.
Table XI-1 AUXILIARY OUTPUT EVENT SELECTION
DATA EVENT DATA EVENT DATA EVENT
0
/
Burglary Alarm 19 Exit 38 Download In Process
1
/ Fire Alarm 20 Entry or Exit 39 Smoke Power
2
/ 24 Hour Alarm 21 Armed State 40 Short Circuit (Over-current)
3
/ Trouble Alarm 22 Disarmed State 41 Box Tamper
4
/ Tamper Alarm 23 Ready 42 Siren Tamper
5 Yelping Siren (Burglary) 24 Not Ready 43 Any Open
6 Temporal Siren (Fire) 25 Fire 44 Any Short
7 Any Siren 26 Fire Trouble 45 Any Fault (Open/ Short on Non-Fire Zone)
8 Any Bypass 27 Chime 46
/ Any Alarm
9 AC Fail 28
/ Expander Trouble 47 Beeping Keypad
10 Low Battery 29 Dynamic Battery Test Time 48
/ Code Entry (See note below)
11
/ Duress 30 Open Period 49
˜ /
Key FOB Function 1
12
/ Aux 1 Keypad Zone 31 Closed Period 50
˜ /
Key FOB Function 2
13
/ Aux 2 Keypad Zone 32 Listen-In 51 Always ON
14
/ Panic Keypad Zone 33 Line Seizure 52 Alarm Flash
15 Keypad Tamper 34 Ground Start 53 Armed Away
16
/ Autotest 35 Fail To Communicate 54 Armed Stay
17 Alarm Memory 36 Telephone Line Fault 55 Aux Comm Fail
18 Entry 37 Program Mode 56 (CP-01) Progress Annunciation
˜ Events 49 & 50 require one or more of the following to operate: NX-408E, NX-416E, NX-448E wireless
receivers, or NX-1700E card reader.
/ If set to follow condition, these events will be 1 second.
Notes: When Event 48 is programmed, it is possible to program a user code's authorization to select which output(s)
a particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 4 correspond to that code
activating outputs 1 - 4 respectively. (See programming the LED keypads on page 8.)