NX-4 Control
Page 13
FORMAT SELECTIONS
DATA FORMAT DESCRIPTION
0 Local Communicator is disabled
1 Universal 4+2
Two digit event code 1800hz transmit 2300hz handshake double round parity
40pps
2 3+1 fast (or 4+1)
One digit event code 1900Hz transmit 1400Hz handshake double round parity
20pps
3 Reserved Reserved
4 Pager 2 digit event code DTMF transmission
5 3/1 or 4/1 slow 1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
6 3/1 or 4/1 slow 1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
7 3/1 or 4/1 fast 1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
8 3/1 or 4/1 fast 1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
9 3/1 or 4/1 fast with
parity
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
10 3/1 or 4/1 fast with
parity
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
11 4+2 express 2 digit event code DTMF transmission
12 4+2 fast
Two-digit event code 1900hz transmit 1400hz handshake double round parity 20
p.p.s.
13 Ademco Contact ID DTMF (see pages 33-34)
14 SIA FSK (see pages 33-34)
15 Custom format (See location 18, page 16)
REPORTING EVENTS TO PHONE NUMBER 1
Location 4 is used to select which events are reported to Phone #1. If dual or split reporting is not desired, location
4 should be used to select all events to Phone #1. If dual or split reporting is desired, location 4 should be used to
select only those events that should be reported to Phone #1. If no events should be reported to Phone #1, location
4 should be programmed as "0" (disabled).
LOCATION 4 - EVENTS REPORTED TO PHONE # 1 (2 segments, feature selection data)
Segment 1: 1 = Alarms and Alarm Restores.
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut, Bell Cut Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.
Segment 2: 1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Over-current and Restore.
3 = Wireless Sensor Missing and Restore.
4 = Wireless Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Reserved.
8 = Reserved.
Comentarios a estos manuales